Application Notes Description Heavy-duty defines the Model S40. The 1/2″ diameter stem and 1/4″ diameter tip section are designed to withstand high velocity and/or viscous fluids while still providing a fast 3.5 second time constant required for high-temperature short time (HTST) pasteurization processes. Case Study https://burnsengineering.com/wp-content/uploads/2021/03/A130412-high-Vibration-Sanitary-Solution-Series-300.pdf
| Sensor type | RTD (Pt100) or Thermocouple |
|---|---|
| Temperature range | -50 to 200 C (-58 to 392 F) |
| Sensor style | Direct Immersion |
| Sheath diameter | 0.125" |
| Immersion depth | Fixed |
| Process connection | Hygienic Ferrule |
| Instrument connection | M12, 0.5" NPT, NPSM, 3/8" UNF |
| Spring loaded for thermowell | No |
| Wire termination | Cable or Head |
| Hazardous rating | None |
| Sensor type | RTD (Pt100) |
| Temperature range | -50 to 200 C (-58 to 392 F) |
| Sensor style | Direct Immersion |
| Sheath diameter | 0.250", 0.375" |
| Immersion depth | Fixed |
| Process connection | Hygienic ferrule |
Send the model code or describe the application — we reply within one working day.
Authorized distributor of industrial pressure, temperature, flow, humidity and gas analysis instrumentation. We supply the exact model code you specify, with calibration certificates, fast lead times and technical support in English.
No.185, East Jiangtian RD, Songjiang Industrial Park, Shanghai, PRC 201613