Home / Products / Automation Components Inc. / ACI Gas & Air Quality Sensors

ACI · Gas detection

ACI Gas & Air Quality Sensors CO, NO2, VOC and Particulate Types

Carbon Dioxide Sensor, Room Mount, 0-2000 ppm, Temperature, 0-10VDC & 4-20mA

Gas detectionACIOfficial datasheetCalibration certificate

Series overview

Key features & advantages

Key features & advantages

  • Genuine instrument supplied with manufacturer calibration certificate
  • Full datasheet and declaration of conformity available on request
  • Technical selection support from our application engineers
  • Spare parts, accessories and recalibration service

Applications

HVAC duct and filter monitoringClean room and pharmaceutical suite pressurisationFan and blower controlBuilding automation and VAV systemsCompressed air and gas line monitoringLaboratory fume hood control

Series specifications

Supply Voltage24 VAC/VDC ±20%; 50/60 Hz, 10.5 to 40 VDC maximum (Half-wave rectified)
Power Consumption<1W
Wiring Connections0.00232 in² (1.5 mm²) screw terminals
Operating EnvironmentResidential, commercial, and industrial spaces
Operating Temperature Range32ºF to 122ºF (0ºC to 50ºC)
Operating RH Range0 to 85% RH Non-condensing
Warm Up Time<5 minutes (@ full specs 15 minutes)
AccuracyCO21: ±30 ppm and ±3% of reading Note: Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations Temperature: ±1.8ºF (1ºC)
Repeatability±20 ppm ±1% of measured value
Annual Zero Drift<± 0.3% of measurement range
Operating Pressure+1.6% per 0.145 psi (1 kPa) deviation from normal pressure | (1 Atmosphere = 14.7 psi (1.013 KPa))
Sensing MethodSingle beam Non-dispersive Infrared (NDIR)
Sensor Life>15 years In normal Indoor Air Quality (IAQ) applications | Corrosive environments are excluded
Response Time (T1/e)<10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time

Model selection

ACI Gas & Air Quality Sensors — models and variants

ModelRange / specification
Asense RoomCarbon Dioxide Sensor, Room Mount, 0-2000 ppm, Temperature, 0-10VDC & 4-20mA
Asense DuctCarbon Dioxide Sensor, Duct Mount, 0-2000 PPM, Relay and Temperature, LCD, 0-10VDC & 4-20mA
Esense IP54Carbon Dioxide Sensor, 0-2000 PPM, IP54 Enclosure, LCD, 0-10VDC & 4-20mA Output
TSENSECarbon Dioxide Sensor, Analog, Modbus, or BACnet, RH/TEMP, RELAY
Asense-GHCarbon Dioxide Sensor, Greenhouse, 0-2000 PPM, Temp and Relay, Conformally Coated PCB, LCD
Esense RoomCarbon Dioxide Sensor, 0-2000 PPM, Room Mount, 0-10VDC Output, 3 LEDs, Audible Alarm
Esense OutdoorCarbon Dioxide Sensor, 0-2000 PPM, Heated Enclosure w/ Thermostat, 0-10V or 2-10V/4-20mA Output
Esense DuctCarbon Dioxide Sensor, Duct Mount, 0-2000 PPM, 0-10VDC & 4-20mA Output.
NO2 RoomNitrogen Dioxide Sensor, 0-6 PPM Default, (10 PPM Max), Room Mount, 4-20mA, 2-10VDC Output NOTE: The NO2-R is not compatible with the Q4C-II , M-Contr
Particulate Matter Room PM-RPM2.5, Room Mount, 0-500u g/m3, 4-20 mA and 0-10 VDC, Modbus RS-485
NO2 DuctNitrogen Dioxide Sensor, 0-6 PPM Default, (10 PPM Max), Duct Mount, 4-20mA, 2-10VDC Output NOTE: The NO2-D is not compatible with the Q4C-II , M-Contr
CO DuctCarbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Duct Mount, 4-20mA or 2-10VDC Output NOTE: The CO-D is not compatible with the Q4C-II , M-Co

Need a price or technical support?

Send the model code or describe the application — we reply within one working day.

Request a Quote

Authorized distributor of industrial pressure, temperature, flow, humidity and gas analysis instrumentation. We supply the exact model code you specify, with calibration certificates, fast lead times and technical support in English.

No.185, East Jiangtian RD, Songjiang Industrial Park, Shanghai, PRC 201613

Contact

  • Tel: (86) 21-57668388
  • Fax: (86) 21-57653818
  • Email: sales@frossel.com
  • Mon–Fri, 8:30–18:00 (GMT+8)
© 2026 FROSSEL (SHANGHAI) CO., LTD.. All rights reserved.Authorized distributor of DwyerOmega, Process Sensing Technologies, FCI and partner brands.