ACI Pressure Sensors & Transmitters for Differential, Gauge and Static Measurement

GP Harness, 10'(3.1m)

PressureACIOfficial datasheetCalibration certificate

Series overview

Key features & advantages

Key features & advantages

  • Genuine instrument supplied with manufacturer calibration certificate
  • Full datasheet and declaration of conformity available on request
  • Technical selection support from our application engineers
  • Spare parts, accessories and recalibration service

Applications

HVAC duct and filter monitoringClean room and pharmaceutical suite pressurisationFan and blower controlBuilding automation and VAV systemsCompressed air and gas line monitoringLaboratory fume hood control

Series specifications

Supply Voltage250 Ohm Load: +13 to 30 VDC | 500 Ohm Load: +18 to 30 VDC
Reverse Polarity Protection+/- 16 V over 5 minutes
Maximum Load Resistance800 Ohms @ 24 VDC | Formula: (Supply VDC – 8 VDC) / 0.020A
Supply Current25 mA minimum
Output Signals4 to 20 mA (2-Wire, Loop Powered)
Response Time< 1 ms
Accuracy @ 22°C (71.6°F)15 to 60 psig: < +/- 1.0% FS 75 to 300 psig: < +/- 0.5% FS 500 psisg: < +/- 0.5% FS
Stability+/- 0.03% FS @ 0 PSIG; +/- 0.12% FS @ 1000 PSIG
Proof Pressure3x FS
Burst Pressure3x FS
Thermal Shock50 Cycles (105ºC to -40ºC, 0.5 hr soaks @ Temp. (10s Transfer))
Vibration (100 to 2000Hz, 20g Sinusoidal, 3 Axes)300 Cycles (105ºC to -40ºC, 0.5 hr soaks @ Temp. (2s Transfer))
Operating Temperature Range-40 to 257ºF (-40 to 125ºC)
Operating Humidity Range0 to 95% RH, non-condensing

Model selection

ACI Pressure Sensors & Transmitters — models and variants

ModelRange / specification
Gauge Pressure TransducerGP Harness, 10'(3.1m)
WPR2Wet Differential Pressure, 0-3, 0-7.5, 0-15, 0-30 PSID (Default), 20' Cables, Outputs: 0-10 VDC (Default), 0-5 VDC, 4-20mA (Selectable) Note: Order th
DLP [Custom]Differential Low Pressure, 0.10 inWC, Bidirectional, 0.50% Accuracy, w/ Pitot Tube and Din Rail, 4-20mA Output, No Nist, Standard
MLP2Differential Pressure, Panel Mount, 0.1 inWC, UniDirectional, +/- 0.5% FSO, 4-20mA
DLPDifferential Pressure, (0.5% Acc), 0.1, 0.2, 0.5, 1 inWC (Default) , Unidirectional (Default), Bidirectional (Selectable)
AFSDifferential Pressure Switch, 0.05 to 12.0 inWC, SPDT, Auto Reset, Compression Fitting
DBLDifferential Pressure Switch, 0.2 to 2.0 inWC, SPDT, Auto Reset, NEMA 3 Enclosure
SPTStatic Pitot Tube, Aluminum, 3.5" Downloads
VPTVelocity Pitot Tube, Aluminum, 4" Tube (2), with 0.17"ID X 1/4"OD X 10' Tubing (2) Downloads
PUP Stainless Wall PlatesStainless Wall Plate Pickup Port
PUP RoomRoom Pickup Port, (R) Beige Downloads
PUP Series VerticalOutside Air Pickup Port, Vertical, NEMA 3R Downloads

Need a price or technical support?

Send the model code or describe the application — we reply within one working day.

Request a Quote

Authorized distributor of industrial pressure, temperature, flow, humidity and gas analysis instrumentation. We supply the exact model code you specify, with calibration certificates, fast lead times and technical support in English.