FMA1600 Series Mass and Volumetric Flow Meters

The Omega FMA-1600 Series consists of Mass and Volumetric Flow Meters designed for clean gases. These instruments measure mass flow rate, volumetric flow rate, gas absolute pressure, and gas temperature using a laminar flow element (LFE) to force gas into laminar flow. The series supports applications requiring simultaneous display of multiple parameters without straight pipe runs or warm-up time.

FlowOMEGACalibration certificateTechnical support

Series overview

Key features & advantages

Key features & advantages

  • The Omega FMA-1600 Series consists of Mass and Volumetric Flow Meters designed for clean gases.
  • The series supports applications requiring simultaneous display of multiple parameters without straight pipe runs or warm-up time.
  • The series offers measurement ranges from 0.5 SCCM to 3000 SLM (0 to 1000 SLPM through 0 to 100,000 SLPM in specific configurations).
  • Accuracy is specified as ±(0.8% of rdg + 0.2% FS) per the data sheet specifications table, with a repeatability of ±0.2%.
  • The typical default response time is <10 ms for 63.2% of a step change and is field adjustable via RS232.
  • Operating conditions include an ambient temperature range of -10 to 50°C (14 to 122°F).
  • Maximum pressure rating is listed as 145 psig, with standard output scaled in SCFM or SLPM.
  • The meters provide a turndown ratio of 200:1 and feature NIST Standard certification.

Applications

Compressed air systems and leak surveysNatural gas and biogas measurementCombustion air and stack flowWater and wastewater aerationFood and beverage batchingPharmaceutical process gas

Series specifications

Accuracy± 0.8 %
Accuracy Detail± (0.8% of rdg + 0.2% FS)
Additional Features 1Power Supply Included
CalibrationNIST 5-Point Certificate
Data InterfaceRS232
Display TypeLCD
Electrical Connection8-pin mini DIN
Height4.1 in
Humidity Range0 to 100% RH non-condensing
Measurable Flow Rate125%
Operating Pressure, Max145 psi
Operating Pressure, Min0 psi
Operating Temperature, Max50 °C
Operating Temperature, Min-10 °C
Pressure Drop, Min1 psi
Repeatability± 0.2%
Response Time10 ms
Response Time Note10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable to a certain extent via RS232 communications. The primary trade-off for response time is signal noise
Series IDFMA1600-Series
Span Shift0.02% FS/°C/atm
Supply Current35 mA
Supply Power Note35 mA typical current draw; 100 mA available supply recommended

Need a price or technical support?

Send the model code or describe the application — we reply within one working day.

Request a Quote

Authorized distributor of industrial pressure, temperature, flow, humidity and gas analysis instrumentation. We supply the exact model code you specify, with calibration certificates, fast lead times and technical support in English.

No.185, East Jiangtian RD, Songjiang Industrial Park, Shanghai, PRC 201613

Contact

  • Tel: (86) 21-57668388
  • Fax: (86) 21-57653818
  • Email: sales@frossel.com
  • Mon–Fri, 8:30–18:00 (GMT+8)
© 2026 FROSSEL (SHANGHAI) CO., LTD.. All rights reserved.Authorized distributor of DwyerOmega, Process Sensing Technologies, FCI and partner brands.